Add to Favorites
Share

Portable Tig Welder

  • Description
Product Detail

    Product description:

    The o of MOSFET inverter DC arc welding power source, has a good load sustained rate.

    1,Compact size, light weight and easy operation, it is suitable for all kinds of welding places

    2,The static external characteristic is the descent characteristic

    3,The welder has over voltage protection, under voltage protection, over temperature protection and over current protection function

    4,With high frequency arc starting function, easy to start arc



    Technical Parameters                                                               

    Model

    WS/TIG-200

    WS/TIG-250

    Rated input voltage /frequency

    Single Phase 220V±15%

    Rated input capacity (KVA)

    7.5

    8.8

    Rated input current (A)

    11.4

    13.4

    Rated duty cycle (%)

    60

    Output current range (A)

    10-200

    10-250

    Output no load voltage (V)

    56

    56

    Output current range (A)

    10-160

    10-230

    Exterior size L x W x H (mm)

    450x270x335

    450x270x335

    Weight(kg)

    8

    8

    Products display

    TIG-200-2.jpg

    IGBT??.jpg

    ????.jpg

    ???.jpg

    ??????.jpg

    ??.jpg


    Portable Tig Welder Maintenance Methods


    The power switch indicator light is on, and the fan does not turn or turn to stop several times, without welding output

     

    1) input may be wrong on the 380V power supply, resulting in over-voltage protection circuit start, change to the 220V power, restart it

     

    2) 220V power instability (input line or too long) or input lines overlap in the grid, resulting in an overvoltage protection circuit starting. Increasing the input line grid line diameter or fastening input line node, this phenomenon in the off 2-3 minutes after the restart recovery

     

    3) continuous open and close power switch in a short time, cause over-voltage protection circuit start, shutdown, wait 2-3 minutes to restart

     

    4) the wires between the switches to the power board are loosened and re tightened

     

    5) the main circuit of the power board, 24V relay is not attracted or damaged, check the 24V power box, relay, such as damage to the relay, the model can be replaced by other electrical equipment